Highway Operations Center Layer-3 Backbone
Section/regional highway ops centers use L3 core switches for multi-section aggregation and upper-tier interconnect.
1. Scenario
Ops centers aggregate multi-station video/EM data and peer with provincial/police platforms—need L3 and 10G-class cores.
2. Challenges
Address clashes across sections; bursty video retrieval; strict security zones.
3. Architecture
Core: PH-4M32P-M; station MDFs: 24GE uplink; critical rings via multi-SFP 8GE switches.
4. Recommended Leagrid LGS2000 products
- LGS2000-PH-4M32P-M: Layer-3 industrial core: 4×10G + 8 Combo + 8 GE fiber + 16 GE copper, 19″ 1U—campus/backbone routing.
- LGS2000-24GE4GF-M: Managed rack aggregation: 24×GE copper + 4×GE SFP for station/central-room aggregation.
- LGS2000-8GE4GF-M: Managed Gigabit switch: 8×GE copper + 4×GE SFP for multi-direction fiber rings and multi-camera uplinks.
5. Deployment notes
Unified IP/routing; 10G for video/platform; security domains per regulation; change control with rollback.